Part Number Hot Search : 
MTRPB DSP563 106KA SC34063 03L3D1V MAX7444 13NK60 03L3D1V
Product Description
Full Text Search
 

To Download 2036-09-A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  features n balanced mini-trigard? n 5 mm diameter, 7.5 mm long n ul recognized n rohs compliant* versions available applications n telecommunications n industrial electronics n commercial electronics n consumer electronics n automotive, aircraft, military electronics characteristics 2036 series - miniature 3-pole gas discharge tube *rohs directive 2002/95/ec jan. 27, 2003 including annex and rohs recast 2011/65/eu june 8, 2011. specifcations are subject to change without notice. the device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. users should verify actual device performance in their specifc applications. test methods per itu-t k.12, ieee c62.31 and iec 61643-311 gdt standards. characteristic model no. 2036-07 2036-09 2036-15 2036-20 2036-23 2036-25 dc sparkover 20 % @ 100 v/s 75 v 90 v 150 v 200 v 230 v 250v impulse sparkover (1) 100 v/s 1000 v/s 250 v 525 v 250 v 550 v 350 v 500 v 425 v 575 v 450 v 600 v 475 v 625 v impulse transverse delay .................. 1000 v/s ............................................................................... < 75 ns insulation resistance ......................... 100 v (50 v for model 2036C07 & 2036-09) ........................... > 10 10 glow voltage ...................................... 10 ma ..................................................................................... ~ 70 v arc voltage ......................................... 1 a .......................................................................................... ~ 10 v glow-arc transition current ............................................................................................................... < 0.5 a capacitance ........................................ 1 mhz ..................................................................................... < 2 pf dc holdover voltage (2) ....................... 135 v, (52 v for model 2036-07 & 2036-09, ........................... < 150 ms 80 v for model 2036-15) impulse discharge current ................. 20000 a, 8/20 s (3) ................................................................. 1 operation minimum 10000 a, 8/20 s .................................................................... > 10 operations 2000 a, 10/350 s .................................................................. 1 operation 200 a, 10/1000 s ................................................................. > 300 operations 200 a, 10/700 s ................................................................... > 500 operations alternating discharge current ............ 20 arms, 1 s (3) ........................................................................ 1 operation minimum 10 arms, 1 s ........................................................................... > 10 operations storage temperature .......................................................................................................................... -55 to +105 c operating temperature ....................................................................................................................... -55 to +105 c climatic category (iec 60068-1) ........................................................................................................ 55/105/21 an optional switch-grade fail-short device is available. the optional fail-short assembly will activate at a temperature of 215 c C 217 c to provide a high conductive path to ground in case of a thermal overload. gdts equipped with the optional fail-short device should be soldered either manually at a temperature that is below the activation temperature of the fail-short mechanism, or using a selective soldering process that does not exceed 210 c. notes: ? ul recognized component, ul file e153537. ? no model number marking on tube; date code and voltage only: month year digits, xxxv (e.g. 0209 400v). ? the rated discharge current for mini-trigard? gas discharge tubes is the total current equally divided between each line to ground. ? sparkover limits after life 25 %, ir >10 8 (-25 %,+30 % for model 2036-07, 2036-09 and 2036-60). ? operating characteristics per rus pe-80 and telcordia gr 1361 available, contact factory. ? line to line voltage is approximately 1.8 to 2 times the stated line to ground breakdown voltage. ? at delivery aql 0.65 level ii, din iso 2859. (2) network applied. (3) dc sparkover may exceed 25 % after discharge, but will continue to p rotect without venting. characteristic model no. 2036-30 2036-35 2036-40 2036-42 2036-47 2036-60 dc sparkover 20 % @ 100 v/s 300 v 350 v 400 v 420 v 470 v 600 v impulse sparkover (1) 100 v/s 1000 v/s 500 v 650 v 600 v 750 v 650 v 825 v 675 v 850 v 750 v 950 v 850 v 1100 v *rohs compliant lead free *rohs compliant versions available lead free versions are rohs compliant* (1) impulse sparkover voltage is defned as typical values of distribution.
specifcations are subject to change without notice. the device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. users should verify actual device performance in their specifc applications. 2036 series - miniature 3-pole gas discharge tube product dimensions 2036-xx-a dia. 5.0 0.3 (.197 .012) 7.5 0.3 (.295 .012) dia. 0.8 0.04 (.031 .002) 0.9 0.3 (.035 .012) 2036-xx-b2 dia. 0.8 0.04 (.031 .002) 4.0 0.4 (.157 .016) 4.4 0.3 (.173 .012) 4.4 0.3 (.173 .012) 2036-xx-b dia. 0.8 0.04 (.031 .002) 25.5 0.6 (1.00 .024) 4.0 0.4 (.157 .016) dimensions: mm (inches) fail-short configuration 2036-xx-b2f shown 6.2 0.3 (.244 .012) 5.3 0.3 (.209 .012) dia. 0.8 0.04 (.031 .002) 2036-xx-b3 dia. 0.8 0.04 (.031 .002) 4.0 0.4 (.157 .016) 3.8 0.3 (.150 .012) 3.8 0.3 (.150 .012)
2036 - xx - x (n) f lf model number designator voltage (divided by 10) 07 = 75 v 30 = 300 v 09 = 90 v 35 = 350 v 15 = 150 v 40 = 400 v 20 = 200 v 42 = 420 v 23 = 230 v 47 = 470 v 25 = 250 v 60 = 600 v leads a = none b = 0.8 mm lead shape (see product dimension drawings) fail-short option blank = standard product f = with fail-short mechanism rohs compliant option blank = standard product lf = rohs compliant product how to order rev. 02/16 specifcations are subject to change without notice. the device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. users should verify actual device performance in their specifc applications. 2036 series - miniature 3-pole gas discharge tube switch-grade fail-short device shorting curve 2036-xx-xf 1.0 10.0 5.0 0.5 current (a) (el tgs) 0.1 0.1 11 0 el tgs = each line to ground simultaneously note: when using a gdt failsafe device, it is imperative that all components associated and connected to the gdt with failsafe be tested in their respective completely integrated environment (finished product) to assure proper operation. seconds 100 packaging specifcations model standard packaging quantity bulk (bag) tray box 2036-xx-a 250 1000 2036-xx-b 100 700 2036-xx-b2 100 900 2036-xx-b3 100 900 2036-xx-b2f 100 900


▲Up To Search▲   

 
Price & Availability of 2036-09-A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X